Electrical panels
& full EPC.
Every SMIPL panel is fabricated in our own Delhi shop, to drawings signed off by our own engineers, tested at our own FAT bench, and shipped with our own name on the documentation. Single-point accountability from design to dispatch — and every year since 2009.
Six panel types.
One in-house shop.
From 63A SMDBs for a single floor to 2000A main LT panels for substation duty — all fabricated, tested and dispatched from our Delhi facility.
Low-Tension Distribution
Main LT distribution panels, sub-distribution panels (SMDBs), lighting panels — up to 2000A, 415V 3-phase, IP42 indoor / IP55 outdoor construction.
- Rating: Up to 2000 A
- Construction: Floor / Wall
- Form: Form 3b / Form 4
High-Tension Switchgear
HT switchgear and VCB panels up to 33 kV. Fabricated in accordance with IS 13118 and IEC 62271. Full type-test certification from CPRI/ERDA accredited labs.
- Rating: Up to 33 kV
- Standard: IEC 62271 / IS 13118
- Type-Tested: CPRI / ERDA
Auto Power Factor Correction
Microprocessor-controlled APFC panels with contactor-switched capacitor banks, harmonic-rated for modern load profiles. Typical improvement: 0.65 to 0.99 power factor.
- Steps: 6 / 8 / 12 / 16
- Capacitors: EPCOS / Schneider
- PF Target: 0.99 lagging
Motor Control Centres
Drawout-type MCCs for process industries. Single-starter or multi-starter configurations with DOL, Star-Delta, VFD and soft-starter feeder options. SCADA-ready with optional Modbus/Profinet I/O.
- Type: Fixed / Drawout
- Starter Types: DOL · S-D · VFD · SS
- Comms: Modbus · Profinet
Power Control Centres
Main incomer panels with ACB-based protection, metering, and outgoing feeders. Built for substation duty with short-circuit ratings up to 50 kA for 1 second.
- Short-Circuit: Up to 50 kA / 1s
- Metering: Multi-function
- Breakers: ABB · Schneider · L&T
Auto Mains Failure
DG-synchronisation and changeover panels with ATS, load management, and full remote monitoring. Sized to DG ratings from 62.5 kVA up to 1500 kVA.
- DG Range: 62.5 – 1500 kVA
- Controllers: Deep Sea · ComAp
- Remote Monitoring: BMS-ready
From requirement
to site-ready.
Six gated stages. Every panel passes through each one. No shortcuts, no exceptions.
Design & SLD
Single-line diagram, GA drawing, BOM freeze with OEM part numbers.
Sheet-Metal
CNC-cut enclosures, powder-coated RAL 7032 / 7035, IP-rated gaskets.
Busbar & Wiring
Tinned copper busbar to IS-5578/8084. Colour-coded wiring, ferrule identification.
Component Fitment
ABB/Siemens/Schneider breakers, Deep Sea controllers, L&T metering.
FAT Testing
HV test 2.5 kV/1-min, IR test, functional test. Client witness optional.
Dispatch & SITC
Packaging, shipment, site installation, commissioning, training, handover.
Only tier-1 OEMs.
Panels are only as reliable as their switchgear. We use only established brand breakers, meters and controllers — with traceable serials and genuine warranties.
Built to PSU-grade specifications.
Every SMIPL panel conforms to Indian and international electrical standards. Our documentation survives any PSU audit.
Have a panel spec
or an EPC requirement?
Share your SLD or BOQ. We'll respond with an engineered quote, lead-time estimate, and a test-plan that matches your specification exactly.