A data centre is one of the hardest coordination problems in EPC. Nine disciplines, a dozen OEMs, zero tolerance for downtime. SMIPL delivers them end-to-end from a single contract — Tier-III aligned, single-vendor accountable, designed to outlive the equipment they house.
Tier-III isn't just a certification. It's a physical design principle: any single component can fail or be taken offline for maintenance without interrupting IT load. Every SMIPL data centre is designed against this standard.
Power, cooling, network — no single point of failure. One unit fails or goes offline for maintenance: load continues uninterrupted. Sized for concurrent maintainability.
Tier-III's design availability translates to ~1.6 hours of downtime per year. Our build process targets this number — and supports it post-commissioning with defined CAMC SLAs.
Comprehensive AMC with on-call engineering response. Remote diagnostics via VPN. OEM-certified spares held in-country. Escalation matrix documented and rehearsed.
The data-centre industry's dirty secret: most "integrators" subcontract half of this list. We don't. Every discipline below is owned in-house or by long-standing partners we warranty ourselves.
Raised-floor engineering rated for server-rack weight. Moisture-resistant construction. Under-floor cable management for optimal airflow.
In-house panel fabrication. Selective coordination design. ABB/Siemens/Schneider breakers. Factory-tested before dispatch.
Redundant online UPS sized for concurrent maintenance. SMF battery banks with defined ride-through time. Remote battery monitoring.
Hot-aisle / cold-aisle containment. Humidity and particulate control. Redundant CRACs — any single unit failure without impact.
Cat-6A and fibre backbones to EIA/TIA. Colour-coded by function. Non-perishable labelling. Full documentation with as-built diagrams.
Clean-agent suppression (FM-200 or NOVEC). VESDA very-early smoke detection. Gas-release interlocks with HVAC and access control.
Biometric + card access at server-room perimeter. In-room surveillance for audit trail. All integrated into central VMS / ICCC.
Unified dashboard: power, cooling, fire, access, environment. Threshold alerts, trend data, maintenance scheduling. SCADA-ready.
Full SAT with client witnessing. Operator training. Multi-year comprehensive AMC with defined response SLAs.
SMIPL's data-centre builds host the AI-enabled Integrated Command & Control Centre infrastructure for Western Coalfields Limited and South Eastern Coalfields Limited. Nine disciplines, single contract, zero finger-pointing. 24×7 operations since commissioning.
Read the Full Case Study →
From 5-rack edge facilities to 500-rack enterprise centres — SMIPL delivers end-to-end. Share your IT load, space available, and target tier. We'll respond with a phased design and budget.